4K Closed Cycle Cryostat

CCS (Closed Cycle System) refrigerator utilizes the principle of G-M thermodynamic cycle to compress and expand helium. The gas is expanded and cooled in the cold head, and the expanded low-pressure helium gas is returned to the compressor, and the cycle is repeated. The refrigerator consists of two stages, the first stage is used to cool the heat shield around the sample, and the second stage is used to cool the sample.
  •  

    CCS (Closed Cycle System) refrigerator utilizes the principle of G-M thermodynamic cycle to compress and expand helium. The gas is expanded and cooled in the cold head, and the expanded low-pressure helium gas is returned to the compressor, and the cycle is repeated. The refrigerator consists of two stages, the first stage is used to cool the heat shield around the sample, and the second stage is used to cool the sample.

    The 4K closed cycle cryostat provided by Jinzhengmao Technology Co., Ltd. is a variable temperature and low temperature platform based on G-M refrigerators produced by domestic and foreign companies. Warm, easy to operate, and low maintenance cost.

    Scope of use:It is mainly used for magnetic measurement, optical measurement, photoelectric reaction, light reflection, fluorescence and magnetoresistance in low temperature and vacuum environment.

    Sdvantage:

    ※ Compact structure, high cost performance, no refrigerant consumption when reaching low temperature, long maintenance period, strong expansibility, and easy to use;
    ※ The sample is in a high vacuum environment or atmosphere;
    ※ Can be integrated with optical windows, a variety of optional window materials;
    ※ A variety of gold-plated oxygen-free copper sample holders can meet the measurement needs of different experimental requirements, and the sample holders can be quickly replaced;
    ※Suitable for electrical, optical and magnetic measurements in low temperature environments;
    ※Silicon diode thermometer or Cernox thermometer (used in strong magnetic field) is installed on the cold finger;
    ※The compressor can be air-cooled or water-cooled, and the maintenance cycle is long;
    ※A variety of options can meet the measurement needs of different experiments.
     

    Sample Holder Options

    Model

    Specifications and Parameters

    Illustrate

    Remark

    T8015

    15*25mm

    Additional electrical sample holder with 8 binding posts above and below

    1. All standard 10K thermostats are equipped with a sample holder by default. The size can be made according to the standard, or it can be designed according to the specific requirements of the user. If the design is more complicated, a fee can be charged as appropriate;
    2. Comes with an optical sample holder as standard, and comes with a sample press. There are holes on the pressing sheet, and the diameter is the same as the size of the clear hole;
    3. The cooling power of the 10K refrigerator is slightly different, and the size of the sample holder can be adjusted within a certain range according to the specific power.

    T8020

    20*30mm

    Additional electrical sample holder with 8 binding posts above and below

    T8030

    30*35mm

    Additional electrical sample holder with 8 binding posts left and right

    T8040

    40*45mm

    Additional electrical sample holder with 8 binding posts left and right

    T8115

    15*25mm

    Additional optical sample holder with Φ8 through hole in the middle

    T8120

    20*30mm

    Additional optical sample holder with Φ10 through hole in the middle

    T8130

    30*35mm

    Additional optical sample holder with Φ15 through hole in the middle

    T8140

    40*45mm

    Additional optical sample holder with Φ20 through hole in the middle

    T8205

    Φ5mm

    Powder sample container with 5mm window on one side of the container

    T8210

    Φ10mm

    Powder sample container with 5mm window on one side of the container

    Optical window options

    Window Model

    Window Specification

    Illustrate

    Remark

    W-20

    Φ20*1.5mm

    Additional Quartz Windows

    1The specifications of the window are all visible area, and the actual size is larger than the visible area;

    2For window installation, you can choose O-ring compression or low-temperature epoxy resin bonding. If the size of the vacuum cover is small, try to use glue.

    W-40

    Φ40*2mm

    Additional Quartz Windows

    K9-W20

    Φ20*1.5mm

    Additional K9 window

    K9-W20

    Φ40*2mm

    Additional K9 window

    F-W20

    Φ20*1.5mm

    Additional calcium fluoride window

    F-W40

    Φ40*2mm

    Additional calcium fluoride window

    Cable options

    Name

    Illustrate

    Remark

    PTFE Wire

    Ordinary wire, large heat leakage, diameter between 0.1-0.3

    The cable is not required to use a common PTFE wire alone, it is required to be made according to the requirements, and the wire should be used in conjunction with the corresponding connector.

    Low Temperature Coaxial Cable

    Low signal interference and accurate measurement

    Phosphor Bronze Twisted Pair

    Poor thermal conductivity, small heat leakage, diameter 0.2mm (4 pieces)

    Microwave Semi-rigid Cable

    High frequency cable, high frequency signal use

    Connector options

    Electrical Connector Model

    Specifications And Parameters

    Describe

    T91-8P Ordinary Glass Sintering

    8pin

    Add a quick-plug 8P common electrical connector

    T91-12P Ordinary Glass Sintering

    12pin

    Add a quick-plug 12P common electrical connector

    T91-SMA

    0-18GHz

    With flexible cable

    0-12.4GHz

    With semi-rigid, semi-flexible cable

    T91-BNC

    0-4GHz

    With ordinary coaxial cable

    T91-TRX

    Triax Connector

    Add a quick-plug triax connector

    T91-S

    Stainless Steel Junction Box

    Add a stainless steel junction box

    T91-PTEF

    PTFE wiring cover

    Add a Teflon junction cover to the stainless steel junction box

     

    Remark:

    1All thermostats are shipped with two connectors, one for temperature sensor and heater installation, and the other for other performance measurements. When more test leads are required, additional mounting holes are required. , or install one or more Breakout Boxes.

    2There is T91-S option in the above table, this option terminal board and shell form the grounding integrally, the other is T91-PTEF option, this option is the use of PTFE board insulation connection in the shell and the installed connector, the shell and the The electrical properties of the joints are independent of each other. Pay attention to this when selecting.

     

联系我们

首页    Closed cycle thermostat    4K Closed Cycle Cryostat