10K Closed Cycle Cryostat
-
CCS (Closed Cycle System) refrigerator utilizes the principle of G-M thermodynamic cycle to compress and expand helium. The gas is expanded and cooled in the cold head, and the expanded low-pressure helium gas is returned to the compressor, and the cycle is repeated. The refrigerator consists of two stages, the first stage is used to cool the heat shield around the sample, and the second stage is used to cool the sample.
The 10K closed cycle cryostat provided by Jinzhengmao Technology Co., Ltd. is a variable temperature and low temperature platform based on G-M refrigerators produced by domestic and foreign companies. Warm, easy to operate, and low maintenance cost.
Scope of use:It is mainly used for magnetic measurement, optical measurement, photoelectric reaction, light reflection, fluorescence and magnetoresistance in low temperature and vacuum environment.
Sdvantage:
※ Compact structure, high cost performance, no refrigerant consumption when reaching low temperature, long maintenance period, strong expansibility, and easy to use;
※ The sample is in a high vacuum environment or atmosphere;
※ Can be integrated with optical windows, a variety of optional window materials;
※ A variety of gold-plated oxygen-free copper sample holders can meet the measurement needs of different experimental requirements, and the sample holders can be quickly replaced;
※Suitable for electrical, optical and magnetic measurements in low temperature environments;
※Silicon diode thermometer or Cernox thermometer (used in strong magnetic field) is installed on the cold finger;
※The compressor can be air-cooled or water-cooled, and the maintenance cycle is long;
※A variety of options can meet the measurement needs of different experiments.
The standard configuration:
※ A set of vacuum hood
※ One temperature sensor and one temperature control heater
※ A gold-plated oxygen-free copper sample holder
※ Vacuum port KF25
※ Air release valve KF16
※ An 8pin electrical vacuum connector, a temperature sensor and a heater share a 6-pin connector
※ Matching compressor, cold head drive line, high pressure helium gas pipe and Toolkit.
※ A set of standard cold head placement bracket
Use:
※ It is mainly used for magnetic measurement, optical measurement, photoelectric reaction, light reflection, fluorescence and magnetoresistance in low temperature and vacuum environment, including material research, superconductivity, cold pump, cold screen and helium liquefaction test.
※ Matrix isolation
※ High temperature (700K) DLTS test
※ Mössbauer spectrum
※ High Tc
※ PL spectrum
※ Photoelectric effect
※ UV/VIS/IR spectrum test
Optional:
※ Rotary vacuum hood
※ Atmosphere introduction end
※ Larger sample space
※ Various low temperature electrical leads (coaxial wire, tee shaft, phosphor bronze twisted pair, microwave semi-steel cable, etc.)
※ DLTS four-probe sample holder
※ Electrical connectors (BNC, SMA, SMK and multi-pin connectors)
※ Special shaped window (such as concave window), fifth window (bottom window)
Sumitomo 10K Closed Cycle Cryostat
Commonly Used 10K Refrigerator Cold Head And Compressor Technical Specifications And Parameters
Cold Head Model
CH-202
CH-204
CH-204N(Optional)
KDE210SA
Low Temperature As Low As
10K
10K
6.5K
10K
Cooldown
90min to 20K
40min to 20K
60min to 10K
60min to 10K
Cooling Capacity
1.8W@20K&7.3K@77K
6.7W@20K&13.5W@80K
2.5W@20K&
2.5W@20K&40W@45K
Cold Head Weight
6.8Kg
7.8Kg
7.8Kg
17.8Kg
Compressor
HC-4E(water cooling )
KDC6000V(water cooling)
Power Consumption
2.6KW at 50Hz/1Phase
7.2KW at 50Hz/3Phase
Cooling Water Inlet Flow And Temperature
2.7L/min@4-27℃
7-10L/min@(28℃)
Size
504*430*485mm
613*442*600
Compressor Weight
75Kg
118Kg
Maintenance Cycle
30 000h
36 months
Integration Specifications And Parameters
Model
Project
CH-202
CH-204
CH-204N(Optional)
KDE210SA
Temperature Range
10K-325K
Required Vacuum
≤1Pa
Experiment Type
Electricity
Optics
Electricity
Optics
Electricity
Optics
Sample Holder Size
15*25mm
15*25mm center opening Φ10mm light hole
20*30mm
20*30mm center open Φ10mm light hole
15*25mm
15*25mm center opening Φ10mm light hole
Vacuum Hood Size
Φ31.8mm
40*40mm
Φ41.8mm
50*50mm
Φ31.8mm
40*40mm
Sample Holder Terminal
8
None
8
None
8
None
Temperature Sensor/Heater
The standard configuration of the temperature sensor is a silicon diode, and the standard configuration of the heater is 50W
Optical Window
None
1-5
None
1-5
None
1-5
Note: Optical holes can be opened in the middle of the optical sample holder, and the size can be specified by the user.
Sample Holder Options:
Model
Specifications And Parameters
Illustrate
Remark
T8015
15*25mm
Additional electrical sample holder with 8 binding posts above and below.
- 1. All standard 10K thermostats are equipped with a sample holder by default. The size can be made according to the standard, or it can be designed according to the specific requirements of the user. If the design is more complicated, it can be charged as appropriate;
- 2. The standard optical sample holder comes with a sample tablet with a hole on the tablet, the diameter of which is the same as that of the clear hole;
- The cooling power of the 10K refrigerator is slightly different, and the size of the sample holder can be adjusted within a certain range according to the specific power.
T8020
20*30mm
Additional electrical sample holder with 8 binding posts above and below.
T8030
30*35mm
Additional electrical sample holder with 8 binding posts left and right.
T8040
40*45mm
Additional electrical sample holder with 8 binding posts left and right.
T8115
15*25mm
Additional optical sample holder with Φ8 through hole in the middle.
T8120
20*30mm
Additional optical sample holder with Φ10 through hole in the middle.
T8130
30*35mm
Additional optical sample holder with Φ15 through hole in the middle.
T8140
40*45mm
Additional optical sample holder with Φ20 through hole in the middle.
T8205
Φ5mm
Powder sample container with 5mm window on one side of the container.
T8210
Φ10mm
Powder sample container with 5mm window on one side of the container.
Optical window options:
Window Model
Window Specification
Illustrate
Remark
W-20
Φ20*1.5mm
Additional Quartz Windows
- 1. The specifications of the window are all visible area, and the actual size is larger than the visible area;
- For window installation, you can choose O-ring compression or low-temperature epoxy resin bonding. If the size of the vacuum cover is small, try to use glue.
W-40
Φ40*2mm
Additional Quartz Windows
K9-W20
Φ20*1.5mm
Additional K9 window
K9-W20
Φ40*2mm
Additional K9 window
F-W20
Φ20*1.5mm
Additional calcium fluoride window
F-W40
Φ40*2mm
Additional calcium fluoride window
Cable Options:
Name
Illustrate
Remark
PTFE Wire
Ordinary wire, large heat leakage, diameter between 0.1-0.3
The cable is not required to use a common PTFE wire alone, it is required to be made according to the requirements, and the wire should be used in conjunction with the corresponding connector。
Low Temperature Coaxial Cable
Low signal interference and accurate measurement
Phosphor Bronze Twisted Pair
Poor thermal conductivity, small heat leakage, diameter 0.2mm (4 pieces)
Microwave Semi-rigid Cable
High frequency cable, high frequency signal use
Connector Options:
Electrical Connector Model
Specifications And Parameters
Describe
T91-8P Ordinary Glass Sintering
8pin
Add a quick-plug 8P common electrical connector.
T91-12P Ordinary Glass Sintering
12pin
Add a quick-plug 12P common electrical connector.
T91-SMA
0-18GHz
With Flexible Cable
0-12.4GHz
With semi-rigid, semi-flexible cable
T91-BNC
0-4GHz
With Ordinary Coaxial Cable
T91-TRX
Triax Connector
Add a quick-plug triax connector.
T91-S
Stainless Steel Junction Box
Add a stainless steel junction box.
T91-PTEF
PTFE Wiring Cover
Add a Teflon junction cover to the stainless steel junction box.
Remark:
1: All thermostats are shipped with two connectors, one is for temperature sensor and heater installation, and the other is for other performance measurements. When more test wires are required, it is necessary to increase Mounting holes, or add one or more Breakout Boxes.
2: There is T91-S option in the above table, the terminal board and the shell of this option constitute the grounding as a whole, and the other is the T91-PTEF option, this option is the shell and the installed joint using PTFE board insulation connection, The electrical properties of the housing and the connector are independent of each other. This should be taken into account when selecting models.
Water cooler selection:
There are split and integrated options, please refer to the water cooler color page for details.
The standard configuration of mechanical pump and molecular pump is a mechanical pump. If higher vacuum is required, domestic and foreign molecular pumps can be selected. For selection, refer to the vacuum pump selection table.