Liquid Nitrogen Thermostats - Optical

The liquid nitrogen cryostat developed by Jinzhengmao Technology Co., Ltd. uses liquid nitrogen as a cooling medium. The standard thermostat can quickly cool down to the liquid nitrogen temperature (about 20 minutes).
  • Liquid Nitrogen Thermostat - Optical

    The liquid nitrogen cryostat developed by Jinzhengmao Technology Co., Ltd. uses liquid nitrogen as a cooling medium. The standard thermostat can quickly cool down to the liquid nitrogen temperature (about 20 minutes). Its working principle is to install it in the liquid nitrogen chamber inside the thermostat. Enter the liquid nitrogen, adjust the gap between the temperature control plug and the cold finger to keep the heat leakage of the cold finger at a certain value, and then pass the temperature controller independently developed by Jinzhengmao Technology Co., Ltd. and its internal fuzzy control system. Adjust the heating output power, so that the temperature of the thermostat changes rapidly between 80K-600K, and can quickly stabilize to a certain set value. In addition, if the thermostat is equipped with a step-down option, the temperature of the thermostat can be reduced. Dropped to 65K and stabilized at 65K.

        In order to meet the needs of more customers, the company has also developed continuous flow type liquid nitrogen and liquid helium cryostats, so that users do not need to add liquid nitrogen and liquid helium all the time during the experiment, and can measure stably for a long time. When using liquid helium as the low-temperature medium, the low temperature can be as low as 4K, and when using liquid nitrogen as the medium, the low temperature can be as low as 78K. During operation, the low-pressure refrigerant is introduced into the thermostat from the liquid inlet, and then passes through the inside of the thermostat. The capillary tube is introduced into the evaporator at the bottom of the thermostat. The evaporator of the thermostat is also equipped with a heater and a temperature sensor. After the temperature is controlled by the temperature controller, the steam is sprayed into the sample chamber. After cooling the sample, the steam passes through. The gas outlet pipe is discharged into the atmosphere or in the gas recovery device. In the design of this type of thermostat, in order to facilitate the customer to easily load the sample, the sample can be loaded from the top of the thermostat through the sample rod. ratio is smaller and is more suitable for measurements in magnetic fields. After more than ten years of pursuit of product quality and strong support from customers before and after sales, TSKE series low temperature products are your ideal choice.

    Functions and Features: 

    ※ Temperature range (65K~500K), (700K optional) high efficiency and fast cooling speed;

    ※ The sample is in the vacuum chamber, which has an ideal and stable experimental environment;

    ※ The vacuum interlayer is equipped with a low-temperature adsorbent, which can prolong the vacuum holding time and prolong the use time of liquid nitrogen;

    ※ The temperature sensor adopts PT100 platinum resistance with good stability and repeatability;

    ※ A variety of options to meet different testing needs;

    ※ It is convenient to add liquid nitrogen during use;

    ※ The optical sample holder can be equipped with pluggable sample cards, and easy-to-use and beautiful binding posts;

    ※ Can be customized according to customer requirements;

    ※ Standard 8 measuring leads, can be expanded to 32;

    ※ The window comes standard with 2 fused silica windows, which can be expanded to 5, and the window material can be replaced according to user requirements;

    ※ The replacement of samples is convenient and quick, and the sample replacement can be completed within 5 minutes;

    ※ The sample holder can choose liquid sample holder, dust sample holder, solid sample holder and block sample holder.

    Technical Specifications

       Model

    Project

    T9115-4W

    T9115-4W-H

    T9120-4W

    T9120-4W-H

    T9130-4W

    T9130-4W-H

    Temperature Range

    65-325k

    65-500k

    65-325k

    65-500k

    65-325k

    65-500k

    Cooling Time

    ≤25min

    Optical Window

    4个Φ15X1.5

    4个Φ20X1.5

    4个Φ30X1.5

    Test Lead Connector

    Standard 8-pin measurement lead connector, optional coaxial connector and microwave connector

    Sample Holder Size

    15X25mm

    15X25mm

    20X30mm

    20X30mm

    30X40mm

    30X40mm

    Thermometer

    PT100 platinum resistance thermometer (calibrated and uncalibrated, default uncalibrated)

    Temperature Stability

    ±0.01K depends on the temperature controller

    Heater

    30W

    60W

    30W

    60W

    30W

    60W

    Vacuum Interface

    Standard KF25 interface

    Sample Environment

    The sample is placed in a vacuum environment

    Degree Of Vacuum

    ≤1Pa can

    Liquid Nitrogen Holding Time

    6h@80K,5h@100K,3h@200K

    Liquid nitrogen Chamber Volume

    Standard 500ml (can be customized)

    Scope Of Application

    Spectral testing, photoelectric reaction, Raman, electroluminescence, photoluminescence, etc.

     

            Note: 700K high temperature optical thermostat can be customized

    Ordering Instructions:

    Sample Holder Options:

     

    Model

    Specifications And Parameters

     

    Material

     

    Describe

    T9115-4W

    15X25mm

    OFHC

    Standard optical sample holder

    T9115-4W-10LTH

    15X25mm

    OFHC

    Standard optical sample holder with Φ10mm hole in the middle

    T9115-4W-H-10LTH

    15X25mm

    OFHC

    Standard optical sample holder with Φ10mm hole in the middle

    T9120-4W

    20X30mm

    OFHC

    Standard optical sample holder with no hole in the middle

    T9120-4W-15LTH

    20X30mm

    OFHC

    Standard optical sample holder with Φ15mm hole in the middle

    T9120-4W-H-15LTH

    20X30mm

    OFHC

    Standard optical sample holder with Φ15mm hole in the middle

    T9130-4W

    30X40mm

    OFHC

    Standard optical sample holder with no hole in the middle

    T9130-4W-20LTH

    30X40mm

    OFHC

    Standard optical sample holder with Φ20mm hole in the middle

    T9130-4W-H-20LTH

    30X40mm

    OFHC

    Standard optical sample holder with Φ20mm hole in the middle

    PSC-10

    Φ10 window

    quartz

    Powder sample container with 10mm quartz window on one side of the container

     

    Remark:

    1: All standard optical thermostats are shipped with only one sample holder.

       2: If the above standard sample holder can not meet customer needs, it can be customized according to customer requirements.

       3: In order to fix the optical performance samples, all optical thermostats are equipped with a tablet for holding the sample, and the aperture of the tablet is the same as the size of the clear hole.

     

    Thermostat Optical Connector Options:

    Electrical Connector Model

    Specifications And Parameters

    Describe

    T91-8P Ordinary Glass Sintering

    8pin

    Add a quick-plug 8P common electrical connector

    T91-12Pordinary Glass Sintering

    12pin

    Add a quick-plug 12P common electrical connector

    T91-SMA

    0-18GHz

    With flexible cable

    0-12.4GHz

    With semi-rigid, semi-flexible cable

    T91-BNC

    0-4GHz

    With ordinary coaxial cable

    T91-TRX

    Triax Connector

    Add a quick-plug triax connector

    T91-S

    Stainless Steel Junction Box

    Add a stainless steel junction box

    T91-PTEF

    PTFE wiring cover

    Add a Teflon junction cover to the stainless steel junction box

     

    Remark:

    1: All thermostats are shipped with two connectors, one for temperature sensor and heater installation and the other for

    The connectors prepared for other performance measurements, when more test lines are required, it is necessary to add mounting holes, or add one or more Breakout Boxes

    2: There is T91-S option in the above table, the terminal board and the shell of this option constitute the grounding as a whole, and the other is the T91-PTEF option, this option is the shell and the installed joint using PTFE board insulation connection, The electrical properties of the housing and the connector are independent of each other. This should be taken into account when selecting models.

    Decompression accessory options

    The standard thermostat itself does not have special pressure reducing spare parts. When 65K low temperature is required, corresponding pressure reducing accessories need to be configured.

     

     

     