The Helmholtz coil with an outer diameter of 1.0 meters has been successfully delivered

 

Recently, our company successfully installed and delivered an electromagnetic field system designed for a national laboratory.

Helmholtz coil

The maximum outer diameter is 1.0 meter, the overall material is non-magnetic, and the base is fixed with aluminum profiles. The coil can be directly placed on the ground, and the coil position can be locked after adjusting the coil spacing. The magnetic field strength can reach 50 Gauss, water-cooled, and two coils are placed in series. The weight of a single coil is 110KG, and the uniformity of the central area is better than 0.6%.

Excitation power supply JCP25/230V

JCP20/200V excitation power supply

·AC input, single-phase 220V ± 10% (50Hz/60Hz)

·Output voltage range 0- ± 230V, output current range 0- ± 25A, maximum output power 5750W

output

·Resolution 0.1mA

·Accuracy ± 0.01% set value

·Noise/Ripple: ≤ 0.01%

·Stability rate ≤ 50ppm (1 hour)

Load adaptability

·Output impedance>1MW

·Internal configuration output compensation network

Load protection

·Controllable output state

·Linear gradient method for handling sudden changes in current settings

·Linear gradient rate of current 0.01A/s-5A/s

·Internal Overpower Protection

Analog input

Add analog input port to the power supply itself

The range of analog voltage is -5V to+5V

The acceptable waveform of the simulated voltage for the power supply is sine wave and sawtooth wave, with a signal period of 5-30 seconds.

delay

The magnetic field delay after triggering is within 15ms.

U scanning function

·I. Three linear scanning modes in quadrants I-III and I-III-I

·Linear scanning rate range 0.01A/s-5A/s, maximum scanning current setting range 1mA-10A DC

·Smooth zero crossing scan without delay

automatic control

·Standard equipped with RS232 interface

·A complete set of computer interface commands

·The timed continuous triggering output function during the scanning process