Electromagnet Power Supply

Electromagnet Power Supply

Product Description:

This power supply is a high stability bipolar constant current power supply, which is widely used in the excitation of inductive loads such as electromagnets and Helmholtz coils. The power supply adopts a linear power supply structure, with high output current stability and low ripple and noise. The output current of the power supply can continuously change between the positive and negative rated current values, and the current smoothly and continuously cross zero, which can make the electromagnet or coil generate a smooth and stable magnetic field.

With the company's high-precision gauss meter and probe (option), the power supply can work in the magnetic field mode. In the magnetic field mode, the magnetic field value can be directly set, and the power supply will adjust the output current to make the electromagnet quickly reach the set magnetic field, which is convenient and fast, and the magnetic field is stable. The field can be controlled independently at will, or the magnetic field can be continuously scanned. The current mode and the magnetic field mode can be switched at any time according to the needs, and the operation is flexible.

Functions and Features:

1) Bipolar Constant Current Output

l                      The output current of the power supply can be continuously changed between the positive and negative rated current extremes

l                      Current smooth zero-crossing without breakpoint, non-switch commutation

l                      Four-quadrant operation of output current and voltage (suitable for inductive loads)

l                      The current change rate can be set in the range of 0.0007 to 0.3 F.S./s (F.S. is the extreme value of the rated output current)

l                      AC input, single-phase 220V±10% (50Hz/60Hz**z) or three-phase 380V±10% (50Hz/60Hz)

The output voltage range is 0-±200V, the output current range is 0-±1000A, and the output power extreme value is 200KW

2) High Current Stability And Low Ripple

l                      Current stability: better than ±50ppm/h (standard type); better than ±5ppm/h (high stability type)

l                      Current accuracy: ±(0.01% set value + 1mA)

l                      Current resolution: 20 bit, for example 15A power supply, current resolution is 0.03mA

l                      Source effect:  2.0×10-5 F.S. (when the supply voltage changes by 10%, the output current changes)

l                      Load effect:  2.0×10-5 F.S. (when the load changes by 10%, the output current changes)

Current ripple (RMS): less than 1mA

3) Two Output Modes

l                      Current mode: Directly set the current in the magnet or coil

l                      Magnetic field mode: directly set the magnetic field size in the magnet or coil

Closed loop adjustment mode, constant magnetic field value

Note: The magnetic field mode needs to cooperate with the company's high-precision gauss meter and probe.

4) Two Ways Of Operation

l                      Local control adopts high-definition touch screen display and operation

    Remote can be controlled by computer through RS232 interface, RS485, LAN, USB optional

5) Multiple Protection Functions

l                      Input power failure protection (when the input power fails, the internal protection absorbs the reverse energy of the inductive load)

 Overcurrent protection (automatic drop current, uncontrollable overcurrent will turn off the power output and alarm)

 Technical Parameters Of Air-cooled Series Power Supply

Model

JCP-5/40

JCP-5/80

JCP-5/120

JCP-10/40

JCP-10/80

JCP-10/120

Output

Output Type

Bipolar Constant Current Output

Rated Current

±5A

±10A

Rated Voltage

±40V

±80V

±120V

±40V

±80V

±120

Current Stability

Standard type is better than ±50ppm/h; high stability type is better than ±5ppm/h

Current Accuracy

±(0.01% set value + 1mA)

Current Resolution

20 bit

0.01mA

0.02mA

Source Effect

 2.0×10-5 F.S.When the supply voltage changes by 10%, the output current changes

Load Effect

 2.0×10-5 F.S.When the load changes by 10%, the output current changes

Current RippleRMS

1mA

1mA

Current

Rate Of Change

Predetermined Area

0.00070.3 F.S./s

Factory Default

0.5A/s

1A/s

Enter

Power Supply

Single-phase three-wire

Voltage

220VAC ± 10%50/60Hz

Power(KVA)

0.3

0.6

0.8

0.6

1.1

1.5

Load

Require

Resistance

 0.6Ω

 2.0Ω

 4.0Ω

 0.6Ω

 2.0Ω

 4.0Ω

Inductance

01H

Surroundings

Operating Temperature

030

Working Humidity

2090%RH

Cool Down

Cooling Method

Air Cooling

Built-in Gauss MeterOptions

Measuring Range

0±30000

Communication

Communication Interface

RS232RS485, LAN, USB Optional

Electric

Connect

Input Wire Diameter

10A Standard Power Cord

Output Wire Diameter

 1mm2

 2.5mm2

Size

L*W*Hmm

520*445*1774U Chassis

Weight

17kg

19kg

21kg

17kg

19kg

21kg

Technical Parameters Of Air-cooled Series Power Supply

Model

JCP-15/40

JCP-15/80

JCP-15/120

JCP-20/40

JCP-20/80

JCP-20/120

JCP-25/40

JCP-25/70

Output

Output Type

Bipolar Constant Current Output

Rated Current

±15A

±20A

±25A

Rated Voltage

±40V

±80V

±120V

±40V

±80V

±120V

±40V

±70V

Current Stability

Standard type is better than ±50ppm/h; high stability type is better than ±5ppm/h

Current Accuracy

±(0.01% set value + 1mA)

Current Resolution

20 bit

0.03mA

0.04mA

0.05mA

Source Effect

 2.0×10-5 F.S.When the supply voltage changes by 10%, the output current changes

Load Effect

 2.0×10-5 F.S.When the load changes by 10%, the output current changes

Current RippleRMS

1mA

1mA

1mA

Current

Rate Of Change

Predetermined Area

0.00070.3 F.S./s

Factory Default

1.5A/s

2.0A/s

2.5A/s

Enter

Power Supply

Single-phase three-wire

Voltage

220VAC ± 10%50/60Hz

Power(KVA)

0.9

1.5

2.2

1.2

2.1

3.0

1.4

2.2

Load

Require

Resistance

 0.6Ω

 2.0Ω

 4.0Ω

 0.6Ω

 2.0Ω

 4.0Ω

 0.5Ω

 1.0Ω

Inductance

01H

Surroundings

Operating Temperature

030

Working Humidity

2090%RH

Cool Down

Cooling Method

Air Cooling

Built-in Gauss Meter (option)

Measuring Range

0±30000

Communication

Communication Interface

RS232RS485, LAN, USB optional

Electric

Connect

Input Wire Diameter

10A standard power cord (input>2KVA, use 16A power cord)

Output Wire Diameter

 4mm2

 4mm2

 6mm2

Size

 

L*W*Hmm

520*445*1774U chassis

Weight

17kg

19kg

21kg

18kg

20kg

22kg

19kg

21kg

 

Technical Parameters Of Water Cooling Series Power Supply

Model

JCP-50/60

JCP-70/60

JCP-90/70

JCP-130/130

JCP-200/150

JCP-400/150

JCP-1000/100

Output

Output Type

Bipolar constant current output

Rated Current

±50A

±70A

±90A

±130A

±200A

±400A

±1000A

Rated Voltage

±60V

±60V

±70V

±130V

±150V

±150V

±100V

Current Stability

Standard type is better than ±50ppm/h; high stability type is better than ±5ppm/h

Current Accuracy

±0.01% set value + 1mA

Current Resolution

20 bit

0.1mA

0.13mA

0.17mA

0.25mA

0.4mA

0.8mA

2.0mA

Source Effect

 2.0×10-5 F.S.When the supply voltage changes by 10%, the output current changes

Load Effect

 2.0×10-5 F.S.When the load changes by 10%, the output current changes

Current RippleRMS

2 mA

2 mA

2 mA

3 mA

4 mA

10 mA

20 mA

Current

Rate Of Change

Predetermined Area

0.00070.3 F.S./s

Factory Default

5A/s

7A/s

9A/s

13A/s

20A/s

20A/s

20A/s

Enter

Power Supply

Three-phase five-wire

Voltage

380AC±10%50/60Hz

Power(KVA)

4.0

5.5

8.1

20

36

72

122

Load

Require

Resistance

0.2Ω

0.1Ω

0.1Ω

0.2Ω

0.2Ω

0.1Ω

0.02Ω

Inductance

01H

Surroundings

Operating Temperature

040

Working Humidity

2080%RHNo Condensation

Cool Down

Cooling Method

Water Cooling

Cooling power

0.8 KW

0.8 KW

1 KW

1.5 KW

2.2 KW

4.5 KW

1KW

Water flow  3 L/min

Water flow  3 L/min

Inlet Water Temperature

1825 related to ambient temperature and humidity

Built-in Gauss Meter (option)

Measuring Range

0±30000

Communication

Communication Interface

RS232RS485, LAN, USB Optional

Electric

Connect

Input Wire Diameter

 2.5 mm2

 4 mm2

 10 mm2

 16 mm2

 35 mm2

 70 mm2

Output Wire Diameter

 16 mm2

 25mm2

 35mm2

 50mm2

 70mm2

 150mm2

 500mm2

Size

L*W*Hmm

520*445*44510U chassis

Cabinet

Weight

60kg

60kg

60kg

To be tested

 

Note

1: The stability of the current is the relative change of the current under the condition that the current is full-scale output, the power supply warm-up time is greater than 30 minutes, and the measurement time is not less than 1 hour.

2: The basic test software is provided free of charge. (Remote input current, set magnetic field) Additional functions need to be charged separately!

3: The output ripple of the current is the rms value of the AC component on the output current measured by KEITHLEY2700. 

 

 

2022年6月22日 10:43